Figure: 25 TAC ยง289.202(ggg)(1)

 

Operating Mode

Assigned Protection Factors

I. Air Purifying Respirators (Particulateb only)c:
     Filtering faceplate disposabled
     Facepiece, halfe
     Facepiece, full
     Facepiece, half
     Facepiece, full
     Helmet/hood
     Facepiece, loose-fitting
II. Atmosphere Supplying Respirators
     (particulate, gases and vaporsf):
     1. Air-line respirator
          Facepiece, half
          Facepiece, half
          Facepiece, half
          Facepiece, full
          Facepiece, full
          Facepiece, full
          Helmet/hood
          Facepiece, loose-fitting
          Suit 
     2. Self-contained breathing apparatus (SCBA):
          Facepiece, full
          Facepiece, full 
          Facepiece, full 
          Facepiece, full 
III. Combination Respirators
      Any combination of air-purifying
      atmosphere-supplying respirators

 
Negative Pressure 
Negative Pressure 
Negative Pressure 
Powered air-purifying respirators
Powered air-purifying respirators
Powered air-purifying respirators
Powered air-purifying respirators

 

Demand
Continuous Flow
Pressure Demand
Demand
Continuous Flow
Pressure Demand
Continuous Flow
Continuous Flow
Continuous Flow 

Demand
Pressure Demand 
Demand, Recirculating 
Positive Pressure Recirculating 

Assigned protection factor for type and mode of operation as listed above

 
(d)
 10
 100
50
1000
1000
25
 
 
 
10
50
50
100
1000
1000
1000
25
(g)
 
100
i10,000
h100
i10,000

            aThese assigned protection factors apply only in a respiratory protection program that meets the requirements of this section. They are applicable only to airborne radiological hazards and may not be appropriate to circumstances when chemical or other respiratory hazards exist instead of, or in addition to, radioactive hazards. Selection and use of respirators for such circumstances shall also comply with Department of Labor regulations.

            Radioactive contaminants for which the concentration values in Table 1, Column 3 of subsection (ggg)(2)(F) of this section are based on internal dose due to inhalation may, in addition, present external exposure hazards at higher concentrations. Under these circumstances, limitations on occupancy may have to be governed by external dose limits.

            bAir purifying respirators with APF < 100 must be equipped with particulate filters that are at least 95% efficient. Air purifying respirators with APF = 100 shall be equipped with particulate filters that are at least 99% efficient. Air purifying respirators with APFs > 100 shall be equipped with particulate filters that are at least 99.97% efficient.

            cThe licensee may apply to the agency for the use of an APF greater than 1 for sorbent cartridges as protection against airborne radioactive gases and vapors (e.g., radioiodine).

            dLicensees may permit individuals to use this type of respirator who have not been medically screened or fit tested on the device provided that no credit be taken for their use in estimating intake or dose. It is also recognized that it is difficult to perform an effective positive or negative pressure pre-use seal check on this type of device. All other respiratory protection program requirements listed in subsection (x) of this section apply. An assigned protection factor has not been assigned for these devices. However, an APF equal to 10 may be used if the licensee can demonstrate a fit factor of at least 100 by use of a validated or evaluated, qualitative or quantitative fit test.

            eUnder-chin type only. No distinction is made in this paragraph between elastomeric half-masks with replaceable cartridges and those designed with the filter medium as an integral part of the facepiece (e.g., disposable or reusable disposable). Both types are acceptable so long as the seal area of the latter contains some substantial type of seal-enhancing material such as rubber or plastic, the two or more suspension straps are adjustable, the filter medium is at least 95% efficient and all other requirements of this section are met.

            fThe assigned protection factors for gases and vapors are not applicable to radioactive contaminants that present an absorption or submersion hazard. For tritium oxide vapor, approximately one-third of the intake occurs by absorption through the skin so that an overall protection factor of 3 is appropriate when atmosphere-supplying respirators are used to protect against tritium oxide. Exposure to radioactive noble gases is not considered a significant respiratory hazard, and protective actions for these contaminants should be based on external (submersion) dose considerations.

            gNo NIOSH approval schedule is currently available for atmosphere supplying suits. This equipment may be used in an acceptable respiratory protection program as long as all the other minimum program requirements, with the exception of fit testing, are met, for example, subsection (x) of this section.

            hThe licensee should implement institutional controls to assure that these devices are not used in areas immediately dangerous to life or health (IDLH).

            iThis type of respirator may be used as an emergency device in unknown concentrations for protection against inhalation hazards. External radiation hazards and other limitations to permitted exposure such as skin absorption shall be taken into account in these circumstances. This device may not be used by any individual who experiences perceptible outward leakage of breathing gas while wearing the device.